b-maxx-5000-baumuller-vietnam-bo-chuyen-doi-b-maxx-5000-baumuller-vietnam.png

b maXX 5000 Baumuller Vietnam, Bộ chuyển đổi  b maXX 5000 Baumuller Vietnam

 

b maXX 5000

Side-by-side, flexible, and energy-efficient servo converter

Baumüller sets standards with the converter generation b maXX 5000. The further development of the successful b maXX series towards modular systems convinces with high-performance power units in air-cooled, water-cooled and cold plate cooling versions and with flexible expandability and the accessibility to an integrated communication concept. Standardized as well as complex automation solutions can be implemented with Baumüller’s converters and controllers within a power range between 1 and 90 kW.

The machine and installation requirements with regard to future reliability, flexible expansion possibilities and a simple adjustment to changed production processes were already considered during the preliminary development process stages of the b maXX 5000.

Individual modules easily can be removed or added over an integrated drive connect system without having to disconnect the entire drive system.

Safety:

  • Plug-in module, optionally with or without safety functions
  • Three different safety modules with scalable functionality
  • All modules with integrated parameter memory for safe and unsafe data
  • Safety functions according to IEC 61800-5-2
  • Power output for motor brake
  • Choice of safety functions via local safe I/O or EtherCAT FSoE

bm5000 zke
DC link capacity unit for the b maXX 5000 series

 Using the dc link capacity unit at dynamic applications the braking energy can be temporary stored and be used for the following acceleration.

Temporary storage of the braking energy – Low energy demand

Peak load leveling – Reduction of the peak loads with the EVU agreed by contract

Smaller dimensioning of the switching cabinet and the rectifier unit – Low space requirements as well as cost saving are possible

Temporarily stored energy permits the controlled shutting down of the system if disturbances or power failures occur – Reduction of costs by going without an independent power supply (USV)


Technical data b maXX 5000 Mains rectifier units

bm5000 sizes

metric / imperial
  Baugröße Zwischenkreis­leistung [kW] Zwischenkreis­spitzenleistung [kW] Überlast­faktor Abmessungen BxHxT [mm]
 
BM 5030 3 5 7 1,5 75 x 395 x 280 / 210 2)
BM 5031 3 10 15 1,5 75 x 395 x 280 / 210 2)
BM 5032 3 18 27 1,5 75 x 395 x 280 / 210 2)
BM 5043 4 36 54 1,4 100 x 395 x 280 / 210 2)
BM 5044 4 70 70 1,0 100 x 395 x 280 / 210 2)