dau-do-exo1-multiparameter-sonde-ysi-pitesco-vietnam.png

Đầu dò EXO1 Multiparameter Sonde YSI Pitesco Vietnam .

The EXO advanced water quality monitoring platform includes the versatile multiparameter EXO1 sonde for estuarine, surface water, or ground water applications.

Key Benefits
• High-accuracy sensors with on-board memory
• Wireless communications
• Fast response times for profiling and sampling
• Seamless integration into marine, estuarine, freshwater and ground water monitoring systems

Smart Sondes and Sensors
Extremely versatile instrument, allowing the user to automatically configure a sonde with different sensor for different applications in minutes

Accuracy
Tested in a variety of rigorous field conditions as well as lab conditions to ensure accuracy and response times

Sample without Interruption
No matter which EXO sensors users select, other features of the sensors' design make them rugged and durable:

• Wet-mateable connectors resist corrosion
• Isolated components prevent short circuits
• Welded housings and double o-rings prevent leaks
• High-impact plastic and titanium resists breaking
• Built-in antifouling systems protect data integrity
• Low power consumption extends underwater deployments

If you're interested in our sonde with 6-ports for even more water quality monitoring capabilities, visit our EXO2 sonde.

Đầu dò EXO1 Multiparameter Sonde YSI Pitesco Vietnam .

 

Depth / Pressure Rating / Limit

0 to 250 m (0 to 820 ft)

Desktop Software Compatible

KOR for EXO

Flow Cell

Yes

Languages

French, English, Spanish, Chinese, German, Japanese

Logging Capabilities

Yes

Medium

Fresh, sea or polluted water

Memory

512 MB total memory, >1,000,000 logged readings

Multiparameter

Yes

Operating Temperature

-5 to +50°C

Power

2 Alkaline Batteries

Sampling

Yes

Smart Sensors / Ports

Yes

Storage Temperature

-20 to +80°C

Unit of Measure

Parameter Dependent

User Calibratable

Yes

Waterproof

Yes

 

EXO1 Specifications

 

Battery Life

90 days*

Communications

Computer Interface: Bluetooth wireless technology (between sonde and handheld or computer with KOR software), USB
Output Options: USB with signal output adapter (SOA); RS-232 & SDI-12 with DCP-SOA.

Diameter

4.70 cm (1.85 in)

Length

64.77 cm (25.50 in)

Peripheral Ports

1 power communication port

Sample Rate

Up to 4 Hz

Sensor Ports

4

Warranty: 3 mos

Replaceable reagent modules for ammonium, chloride, and nitrate

Warranty: 1 yr

Optical DO membranes and replaceable reagent modules for pH and pH/ORP

Warranty: 2 yrs

Cables; sonde bulkheads; handheld; conductivity, temperature, depth, and optical sensors; electronics base for pH, pH/ORP, ammonium, chloride, and nitrate sensors; and accessories

Weight

1.42 kg (3.15 lbs)

*Typically 90 days at 20˚C at 15-minute logging interval; temperature/conductivity, pH/ORP, DO, and turbidity sensors installed on EXO1. Battery life is heavily dependent on sensor configuration.

EXO Parameter Measured

Sensor**

Range

Accuracy

Response

Resolution

Ammonium
(freshwater only)

Ammonium Sensor
Ammonia with pH sensor
SKU: 599710

0 to 200 mg/L (0 to 30˚C)

±10% of reading or 2 mg/L-N, w.i.g.

T63<30 sec

0.01 mg/L

Barometric Pressure

Integral Barometer

375 to 825 mmHg

±1.5 mmHg from 0 to 50°C

-

0.1 mmHg

Blue-green Algae,
Phycocyanin

Total Algae Sensor

SKU: 599102-01

0 to 100 μg/L;
0 to 100 RFU;

Linearity: R2 >0.999 for serial dilution of Rhodamine WT solution from 0 to 100 μg/mL BGA-PC equivalents

T63<2 sec

0.01 μg/L;
0.01 RFU

Blue-green Algae,
Phycoerythrin

Total Algae Sensor

SKU: 599103-01

0 to 280 μg/L;
0 to 100 RFU;

Linearity: R2 >0.999 for serial dilution of Rhodamine WT solution from 0 to 280 μg/mL BGA-PE equivalents

T63<2 sec

0.01 μg/L;
0.01 RFU

Chloride
(freshwater only)

Chloride Sensor
SKU: 599711

0 to 18000 mg/L-Cl (0 to 30˚C)

±15% of reading or 5 mg/L-Cl, w.i.g.

T63<30 sec

0.01 mg/L

Chlorophyll

Total Algae Sensor

SKU: 599102-01599103-01

0 to 400 μg/L Chl;
0 to 100 RFU

Linearity: R2 >0.999 for serial dilution of Rhodamine WT solution from 0 to 400 μg/L Chl a equivalents

T63<2 sec

0.01 μg/L Chl;
0.01 RFU

Conductivity1

Conductivity / Temperature Sensor
SKU: 599870

0 to 200 mS/cm

0 to 100: ±0.5% of reading or 0.001 mS/cm, w.i.g.;
100 to 200: ±1% of reading

T63<2 sec

0.0001 to 0.01 mS/cm (range dependent)

Depth - 10 m

Integral, Non-vented Depth Sensor3

0 to 10 m
(0 to 33 ft)

±0.04% FS (±0.004 m or ±0.013 ft)

T63<2 sec

0.001 m (0.001 ft)
(auto-ranging)

Depth - 100 m

Integral, Non-vented Depth Sensor3

0 to 100 m
(0 to 328 ft)

±0.04% FS (±0.04 m or ±0.13 ft)

T63<2 sec

0.001 m (0.001 ft)
(auto-ranging)

Depth - 250 m

Integral, Non-vented Depth Sensor3

0 to 250 m
(0 to 820 ft)

±0.04% FS (±0.10 m or ±0.33 ft)

T63<2 sec

0.001 m (0.001 ft)
(auto-ranging)

Dissolved Oxygen, % air saturation

Optical Dissolved Oxygen Sensor
SKU: 599100-01

0 to 500%
air saturation

0 to 200%: ±1% of reading or 1% saturation, w.i.g.;
200 to 500%: ±5% of reading 4

T63<5 sec5

0.1% air saturation

Dissolved Oxygen, mg/L

Optical Dissolved Oxygen Sensor
SKU: 599100-01

0 to 50 mg/L

0 to 20 mg/L: ±0.1 mg/L or 1% of reading, w.i.g.;
20 to 50 mg/L: ±5% of reading 4

T63<5 sec5

0.01 mg/L

fDOM
(CDOM)

fDOM Sensor
SKU: 599104-01

0 to 300 ppb Quinine Sulfate equivalents (QSU)

Linearity: R2 > 0.999 for serial dilution of 300 ppb QS solution
Detection Limit: 0.07 ppb QSU

T63<2 sec

0.01 ppb QSU

Level, Vented - 10 m

Integral Vented Level Sensor

0 to 10 m (0 to 33 ft)

±0.03% FS (±0.003 m or ±0.010 ft)

T63<2 sec

0.001 m (0.001 ft)

Nitrate
(freshwater only)

Nitrate Sensor
SKU: 599709

0 to 200 mg/L-N (0 to 30˚C)

±10% of reading or 2 mg/L-N, w.i.g.

T63<30 sec

0.01 mg/L

pH

pH Sensor
SKU:599701 guarded599702 unguarded

pH/ORP Sensor
SKU:599705 guarded599706 unguarded

0 to 14 units

±0.1 pH units within ±10˚C of calibration temp;
±0.2 pH units for entire temp range7

T63<3 sec8

0.01 units

ORP

pH/ORP Sensor
SKU:599705 guarded
599706 unguarded

-999 to 999 mV

±20 mV in Redox standard solution

T63<5 sec6

0.1 mV

Temperature

Conductivity / Temperature Sensor
SKU: 599870

-5 to 35°C
35 to 50°C

±0.01°C2
±0.05°C2

T63<1 sec

0.001 °C

Turbidity9

Turbidity Sensor
SKU: 599101-01

0 to 4000 FNU

0 to 999 FNU: 0.3 FNU or ±2% of reading, w.i.g.;
1000 to 4000 FNU: ±5% of reading10

T63<2 sec

0 to 999 FNU = 0.01 FNU;
1000 to 4000 FNU = 0.1 FNU

Salinity

Calculated from Conductivity and Temperature11

0 to 70 ppt

±1.0% of reading or 0.1 ppt, w.i.g.

T63<2 sec

0.01 ppt

Specific Conductance

Calculated from Conductivity and Temperature11

0 to 200 mS/cm

±0.5% of reading or .001 mS/cm, w.i.g.

-

0.001, 0.01, 0.1 mS/cm
(auto-scaling)

Total Dissolved Solids (TDS)

Calculated from Conductivity and Temperature11

0 to 100,000 mg/L
Cal constant range
0.30 to 1.00
(0.64 default)

Not Specified

-

Variable

Total Suspended Solids (TSS)

Calculated from Turbidity and user reference samples

0 to 1500 mg/L

Not specified

T63<2 sec

Variable

**Specifications indicate typical performance and are subject to change. All sensors have a depth rating to 250 m (820 ft), except shallow and medium depth sensors, ammonium, chloride, and nitrate. Accuracy specification is attained immediately following calibration under controlled and stable environmental conditions. Performance in the natural environment may vary from quoted specification.
w.i.g. = whichever is greater

EXO sensors are not compatible with YSI 6-Series sondes, sensors, or handheld.

1Outputs of specific conductance (conductivity corrected to 25˚C) and total dissolved solids are also provided. See Calculated Parameters and footnote 11.
2 Temperature accuracy traceable to NIST standards
3Accuracy specifications apply to conductivity levels of 0 to 100,000 μS/cm.
4 Relative to calibration gases
5 When transferred from air-saturated water to stirred deaerated water
6 When transferred from water-saturated air to Zobell solution
7Within the environmental pH range of pH 4 to pH 10.
8On transfer from water-saturated air to rapidly stirred air-saturated water at a specific conductance of 800 μS/cm at 20˚C; T63<5 seconds on transfer from water-saturated air to slowly-stirred air-saturated water.
9 Calibration: 1-, 2-, or 3-point, user-selectable
10 Performance based on 3-point calibration done with YSI AMCO-AEPA standards of 0, 124, and 1010 FNU. The same type of standard must be used for all calibration points.
11 Values are automatically calculated from conductivity according to algorithms found in Standard Methods for the Examination of Water and Wastewater (Ed. 1989).

Xenoy is a trademark of SABIC Innovative Plastics IP BV.

EXO Bluetooth modules comply with Part 15C of FCC Rules and have FCC, CE Mark and C-tick approval. Bluetooth-type approvals and regulations can be country specific. Check local laws and regulations to insure that the use of wireless products purchased from Xylem are in full compliance.