displacement-measurement-sensors-od-max-od-25-01t1-cam-bien-do-dich-chuyen-od-max-sick-vietnam.png

OD-25-01T1 , 6030977 , OD85-20T1 , 6028958 , OD30-05T1 , 6028959 , OD350-100T , 6028957, Displacement measurement sensors OD Max OD-25-01T1, Cảm biến đo dịch chuyển  OD Max Sick VietNam.

 

Show all
 
Hide all
  • FEATURES
    System part Sensor head
  • PERFORMANCE
    Measuring range 24 mm ... 26 mm 1)
    Target Natural objects
    Repeatability 0.1 µm 2)
    Linearity ± 2 µm 2)
    Response time ≥ 0.5 ms 3)
    Measuring frequency ≤ 10 kHz
    Output time ≥ 0.1 ms
    Light source Laser, red
    Laser class 1 (IEC 60825-1:2014, EN 60825-1:2014) 4)
    Typ. light spot size (distance) 25 µm x 35 µm (25 mm)
    • 1) 6 % ... 90 % remission.
    • 2) Measurement on 90 % remission (ceramic, white), for OD25-x measurement on mirror, averaging set to: 256, constant ambient conditions.
    • 3) Dependent on the set average or sensitivity.
    • 4) Wavelength: 650 nm, max. output: 390 µW (laser class 1) / 1 mW (laser class 2).
  • INTERFACES
    Serial ✔ , RS-232
    Type of fieldbus integration Optional, over external evaluation unit AOD
    Analog output 2 x 4 mA ... 20 mA (≤ 300 Ω) 1)
    Switching output

    5 x PNP (100 mA) 1)

    5 x NPN (100 mA) 1)

    • 1) Optional over evaluation unit AOD.
  • MECHANICS/ELECTRONICS
    Warm-up time ≤ 5 min
    Housing material Aluminum
    Window material Glass
    Connection type 0.5 m cable with connector 1) 2)
    Indication LEDs, 1.4'' color display on evaluation unit
    Weight 250 g 3)
    Enclosure rating IP67
    Protection class III
    • 1) Can be extended to up to 10 m with extension cable.
    • 2) Sensor must be connected to controller unit.
    • 3) Includes 0.5 m cable.
  • AMBIENT DATA
    Ambient temperature operation –10 °C ... +45 °C
    Ambient storage temperature –20 °C ... +60 °C
    Relative air humidity (non-condensing) 35 % ... 85 %
    Temperature drift ± 0.01 % FS/K (FS = Full Scale = Measuring range of sensor)
    Typ. Ambient light immunity

    Artificial light: ≤ 3,000 lx

    Sunlight: ≤ 10,000 lx

    Vibration resistance 10 Hz ... 55 Hz (amplitude 1.5 mm, x-, y-, z-axis 2 hours each)
    Shock resistance 50 G (x, y, z axis 3 times each)
  • GENERAL NOTES
    Note on use OD Max sensor head OD25-x is only to be used with AODG-P/N1, All other types (OD350-x, OD85-x, OD30-x) are to be used with AOD-P/N1
  • CLASSIFICATIONS
    ECl@ss 5.0 27270801
    ECl@ss 5.1.4 27270801
    ECl@ss 6.0 27270801
    ECl@ss 6.2 27270801
    ECl@ss 7.0 27270801
    ECl@ss 8.0 27270801
    ECl@ss 8.1 27270801
    ECl@ss 9.0 27270801
    ETIM 5.0 EC001825
    ETIM 6.0 EC001825
    UNSPSC 16.0901 41111613