displacement-measurement-sensors-od-value-od2-p250w150i0-cam-bien-do-dich-chuyen-gia-tri-od-sick-ysi-vietnam.png

OD2-P250W150I0, Displacement measurement sensors OD Value OD2-P250W150I0, Cảm biến đo dịch chuyển  Giá trị OD Sick YSI VietNam.

 

PERFORMANCE
Measuring range 100 mm ... 400 mm 1)
Target Natural objects
Repeatability 75 µm 1) 2) 3)
Linearity ± 750 µm 2) 4) 5)
Response time ≥ 1 ms
Measuring frequency ≤ 1.33 kHz 1)
Output time ≥ 0.75 ms
Light source Laser, red
Laser class 2 (IEC 60825-1:2014, EN 60825-1:2014) 6)
Typ. light spot size (distance) 1.8 mm x 3.5 mm (250 mm)
Additional function Mean-value setting 1 … 64x, automatic sensitivity adjustment, Analog outputs can be taught in, Invertable analog output, Teach-in of switching output, Invertable switching output, multifunctional input: laser-off / external teach-in / trigger, switching mode: distance to object (DtO), switching mode: window (Wnd)

 

Analog output 1 x 4 mA ... 20 mA (≤ 300 Ω)
Resolution analog output 16 bit
Switching output 2 x PNP (100 mA) 1)
Multifunctional input (MF) 1 x MF 2)
  • 1) PNP: HIGH = VS - (< 2 V) / LOW = < 2 V, NPN: HIGH = < 2 V / LOW = VS.
  • 2) MF can be used as laser-off, trigger, external teach-in, or deactivated, response time ≤ 3 ms.
MECHANICS/ELECTRONICS
Supply voltage Vs DC 12 V ... 24 V
Power consumption ≤ 2.88 W 1)
Warm-up time ≤ 30 min
Housing material PBT
Window material PMMA
Connection type Male connector, M12, 8-pin, swivel connector unit
Indication Distance bar graph, up to 8 status LEDs
Weight 70 g
Enclosure rating IP67
Protection class III