safety-laser-scanners-s300-professional-may-quet-laser-an-toan-s300-professional-sick-ysi-vietnam.png

S30B-2011DA, Safety laser scanners S300 Professional, Máy quét laser an toàn  S300 Professional Sick YSI VietNam.

 

  • FEATURES
    Protective field range 2 m
    Warning field range 8 m (at 15 % reflectivity)
    Distance measuring range 30 m
    Type of field set Triple field sets
    Number of field sets 8
    Number of fields 24
    Number of monitoring cases 32 1)
    Scanning angle 270°
    Resolution (can be configured) 30 mm, 40 mm, 50 mm, 70 mm
    Angular resolution 0.5°
    Response time 80 ms 2)
    Protective field supplement 100 mm
    Number of multiple samplings 2 ... 16, configurable
    Delay of automatic reset 2 s ... 60 s, configurable
    • 1) In combination with an additional static input via EFI or using the dynamic inputs on the device. Otherwise eight.
    • 2) Depending on basic response time and multiple sampling.
  • SAFETY-RELATED PARAMETERS
    Type Type 3 (IEC 61496)
    Safety integrity level

    SIL2 (IEC 61508)

    SILCL2 (EN 62061)

    Category Category 3 (EN ISO 13849)
    Performance level PL d (EN ISO 13849)
    PFHD (mean probability of a dangerous failure per hour) 8.0 x 10-8 (EN ISO 13849)
    TM (mission time) 20 years (EN ISO 13849)
    Safe state in the event of a fault At least one OSSD is in the OFF state.
  • FUNCTIONS
    Restart interlock
    External device monitoring (EDM)
    Multiple sampling
    Monitoring case switching
    Static protective field switching
    Dynamic protective field switching
    Contour as a reference
    Integrated configuration memory
    Measured data output
    Safe SICK device communication via EFI
  • INTERFACES
    Connection type System plug with or without connecting cable
    Universal I/Os​ 1)
    Inputs  
    External device monitoring (EDM) 2)
    Reset/restart 2)
    Static control inputs 3)
    Static control inputs with EFI 4)
    Dynamic control inputs (incremental encoder) 5)
    Standby 1
    Outputs  
    OSSD pairs 1
    Diagnostic outputs 6)
    Configuration method PC with CDS (Configuration and Diagnostic Software)
    Configuration and diagnostics interface RS-232
    Transmission rate 38.4 kBaud
    Data interface RS-422
    Transmission rate ≤ 500 kBaud
    Safe SICK device communication via EFI  
    Transmission rate ≤ 500 kBaud
    Length of cable ≤ 50 m
    Conductor cross-section 0.22 mm²
    Fieldbus, industrial network  
    Integration via EFI gateways CANopen, Ethernet, PROFIBUS DP, PROFIBUS PROFIsafe, PROFINET PROFIsafe 7)
    • 1) Freely programmable, e.g., external device monitoring input, reset input, contamination warning, reset required.
    • 2) Availability depends on the configuration of the universal I/Os.
    • 3) 2+1, additional input is only available if reset and reset required are not being used.
    • 4) In combination with an EFI device (Flexi Soft or EFI gateway) five static control inputs are available. Otherwise three.
    • 5) Two of the static swichting signals can be used either as dynamic or as static switching signals.
    • 6) Freely programmable, e.g. warning field, contamination, reset required.
    • 7) For a suitable EFI-gateway see modules and gateways in the accessory section of connection systems.
  • ELECTRICAL DATA
    Protection class II (EN 50178, EN 60950)
    Supply voltage Vs 24 V DC (16.8 V DC ... 30 V DC)
    Power consumption

    ≤ 0.33 A 1)

    ≤ 1.7 A 2)

    Outputs  
    Output signal switching devices (OSSDs) 2 x 250 mA
    Diagnostic outputs 3 x 100 mA 3)
    • 1) At 24 V DC without output load.
    • 2) At 24 V DC including maximum output load.
    • 3) Freely programmable, e.g. warning field, contamination, reset required.
  • MECHANICAL DATA
    Dimensions (W x H x D) 102 mm x 152 mm x 106 mm
    Weight 1.2 kg
    Housing material Aluminum die cast
    Housing color RAL 1021 (yellow)
    Optics cover material Polycarbonate
    Optics cover surface finish Outside with scratch-resistant coating
  • AMBIENT DATA
    Enclosure rating IP65 (EN 60529)
    Ambient operating temperature –10 °C ... +50 °C
    Storage temperature –25 °C ... +50 °C
    Vibration resistance 5 g, 10 Hz ... 150 Hz (IEC 61496, IEC 61496-3)
    Shock resistance  
    Continuous shock 10 g, 16 ms (IEC 61496, IEC 61496-3)
  • OTHER INFORMATION
    Type of light Pulsed laser diode
    Wave length 905 nm
    Detectable remission 1.8 % ... > 1,000 %, reflectors
    Laser class 1 (21 CFR 1040.10 and 1040.11, IEC 60825-1)
  • CLASSIFICATIONS
    ECl@ss 5.0 27272705
    ECl@ss 5.1.4 27272705
    ECl@ss 6.0 27272705
    ECl@ss 6.2 27272705
    ECl@ss 7.0 27272705
    ECl@ss 8.0 27272705
    ECl@ss 8.1 27272705
    ECl@ss 9.0 27272705
    ETIM 5.0 EC002550
    ETIM 6.0 EC002550
    UNSPSC 16.0901 39121528
Show all
 
Hide all

Technical drawings

 
S30B-2011DA
Dimensional drawing Laser scanner
S30B-2011DA
Dimensional drawing Origin of scan plane
S30B-2011DA
Connection diagram S300 Professional: protective field switching with two static inputs
 
S30B-2011DA