      Sensor/ detection principle Photoelectric retro-reflective sensor, autocollimation
      Dimensions (W x H x D) 15.6 mm x 48.5 mm x 42 mm
      Housing design (light emission) Rectangular
      Sensing range max. 0 m ... 7 m 1)
      Sensing range 0 m ... 5 m 1)
      Type of light Visible red light
      Light source LED 2)
      Light spot size (distance) Ø 100 mm (3 m)
      Angle of dispersion Approx. 1.5°
      Wave length 640 nm
      Adjustment Potentiometer, 5 turns
      • 1) Reflector PL80A.
      • 2) Average service life: 100,000 h at TU = +25 °C.
    • MECHANICS/ELECTRONICS
      Supply voltage 10 V DC ... 30 V DC 1)
      Ripple ≤ 5 Vpp 2)
      Power consumption 30 mA 3)
      Switching output PNP
      Output function Complementary
      Switching mode Light/dark switching
      Signal voltage PNP HIGH/LOW > Uv - 2,5 V / ca. 0 V
      Output current Imax. 100 mA
      Response time ≤ 330 µs 4)
      Switching frequency 1,500 Hz 5)
      Connection type Male connector M12, 4-pin
      Circuit protection

      6)

      7)

      8)

      Protection class III
      Weight 120 g
      Polarisation filter
      Housing material Metal
      Optics material Plastic, PMMA
      Enclosure rating

      IP66

      IP67

      IP69K

      Items supplied 2 x clamps incl. screws
      Ambient operating temperature –40 °C ... +60 °C
      Ambient storage temperature –40 °C ... +75 °C
      UL File No. NRKH.E181493 & NRKH7.E181493
      • 1) Limit values when operated in short-circuit protected network: max. 8 A.
      • 2) May not exceed or fall below Uv tolerances.
      • 3) Without load.
      • 4) Signal transit time with resistive load.
      • 5) With light/dark ratio 1:1.
      • 6) A = VS connections reverse-polarity protected.
      • 7) C = interference suppression.
      • 8) D = outputs overcurrent and short-circuit protected.
    • CLASSIFICATIONS
      ECl@ss 5.0 27270902
      ECl@ss 5.1.4 27270902
      ECl@ss 6.0 27270902
      ECl@ss 6.2 27270902
      ECl@ss 7.0 27270902
      ECl@ss 8.0 27270902
      ECl@ss 8.1 27270902
      ECl@ss 9.0 27270902
      ETIM 5.0 EC002717
      ETIM 6.0 EC002717
      UNSPSC 16.0901 39121528
    Show all
     
    Hide all

    Technical drawings

     
    WL12-3P2431
    Dimensional drawing WL12-3, WSE12-3
    WL12-3P2431
    Adjustments possible WL12-3, WSE12-3
    WL12-3P2431
    Connection diagram Cd-083
     
    WL12-3P2431
    Characteristic curve WL12-3
    WL12-3P2431