dong-ho-do-ap-suat-dien-tu-el-press-p-502c-bronkhorst-vietnam.png

Đồng hồ đo áp suất điện tử EL-PRESS P-502C Bronkhorst Vietnam

 

EL-PRESS P-502C

Digital Electronic Pressure Meter

  • For absolute or gauge pressure
  • High accuracy and repeatability
  • Well proven, compact thru-flow design
  • On-board PID controller for pressure control
  • Analog, RS232 and fieldbus communication

Technical specifications

Measurement / control system
Absolute pressure sensors Code: 350A Ranges (FS): 100 ... 350 mbara P-max: 1,0 barg Burst pressure: 1,4 barg
Code: 1K1A Ranges (FS): 0,35 ... 1,1 bara P-max: 3,1 barg Burst pressure: 4,2 barg
Code: 6K0A Ranges (FS): 1,1 ... 6 bara P-max: 10,5 barg Burst pressure: 14 barg
Code: 21KA Ranges (FS): 6 ... 21 bara P-max: 62 barg Burst pressure: 84 barg
Code: M10A Ranges (FS): 20 ... 100 bara P-max: 200 barg Burst pressure: n.a.
Relative pressure sensors Code: 100R Ranges (FS): 35 ... 100 mbarg P-max: 0,7 barg Burst pressure: 0,8 barg
Code: 350R Ranges (FS): 100 ... 350 mbarg P-max: 1,0 barg Burst pressure: 1,4 barg
Code: 1K1R Ranges (FS): 0,35 ... 1,1 barg P-max: 3,1 barg Burst pressure: 4,2 barg
Code: 6K0R Ranges (FS): 1,1 ... 6 barg P-max: 10,5 barg Burst pressure: 14 barg
Code: 21KR Ranges (FS): 6 ... 21 barg P-max: 62 barg Burst pressure: 84 barg
Accuracy (incl. linearity and hysteresis) standard: ±0,5% FS
Repeatability < 0,1% Rd
Pressure rangeability 1:50 for pressure meter;
1 : 20 for P2-control; 1 : 5 for P1-control
Response time (sensor) 2 msec
Operating temperature -10…+70°C
Temperature sensitivity 0,1% FS/°C
Leak integrity, outboard tested < 2 x 10-9 mbar l/s He
Attitude sensitivity max. error at 90° off horizontal < 0,3 mbar
Warm-up time negligible
Mechanical parts
Material (wetted parts) stainless steel 316L or comparable
Process connections compression type or face seal couplings
Seals standard: Viton®; options: EPDM, Kalrez® (FFKM)
Weight 0,4 kg
Ingress protection (housing) IP40
Electrical properties
Power supply +15…24 Vdc
Max. power consumption
meter
Supply
15 V
24 V
at voltage I/O
67 mA
49 mA
at current I/O
90 mA
67 mA
Max. power consumption
controller
Supply
15 V
24 V
at voltage I/O
223 mA
150 mA
at current I/O
223 mA
150 mA
PROFIBUS DP add 53 mA (15 V supply) or 30 mA (24 V supply)
PROFINET add 77 mA (15 V supply) or 48 mA (24 V supply)
EtherCAT® add 66 mA (15 V supply) or 41 mA (24 V supply)
DeviceNet™ add 48 mA (24 V supply)
Analog output/command 0...5 (10) Vdc or 0 (4)…20 mA (sourcing output)
Digital communication standard: RS232;
options: PROFIBUS DP, DeviceNet™, PROFINET, EtherCAT®, Modbus RTU or ASCII, FLOW-BUS
Electrical connection
Analog/RS232 9-pin D-connector (male);
PROFIBUS DP bus: 9-pin D-connector (female);
power: 9-pin D-connector (male);
Devicenet™ 5-pin M12-connector (male);
EtherCAT®/ PROFINET 2 x RJ45 modular jack (in/out)
FLOW-BUS/Modbus-RTU/ASCII RJ45 modular jack