Đồng hồ đo lưu lượng nhiệt EL-FLOW SELECT F-112AC Bronkhorst Vietnam
Nhà cung cấp: Pitesco
Hãng sản xuất: Bronkhorst
Đồng hồ đo lưu lượng nhiệt EL-FLOW SELECT F-112AC Bronkhorst Vietnam, đại lý Bronkhorst Vietnam
EL-FLOW SELECT F-112AC
Digital Thermal Mass Flow Meter for Gases
- High accuracy, excellent repeatability
- Optional Multi Fluid / Multi Range functionality
- Virtually pressure and temperature independent
- Compact design
Gas Mass Flow Meters for medium flow rates
Bronkhorst® model F-112AC Mass Flow Meters (MFMs) are suited for precise measurement of flow ranges between 0,8…40 ln/min and 1,4…250 ln/min at operating pressures between vacuum and 100 bar. The MFM consists of a thermal mass flow sensor and a microprocessor based pc-board with signal and fieldbus conversion and a PID controller for optional mass flow control by means of a separately mounted control valve.
EL-FLOW® Select series are equipped with a digital pc-board, offering high accuracy, excellent temperature stability and fast response. The main digital pc-board contains all of the general functions needed for measurement and control. In addition to the standard RS232 output the instruments also offer analog I/O. As an option, an on-board interface can be mounted to provide DeviceNet™, PROFIBUS DP, Modbus, EtherCAT®, PROFINET or FLOW-BUS protocols. The EL-FLOW® Select design features optional Multi Gas / Multi Range functionality, providing (OEM-) customers with optimal flexibility and process efficiency.
Technical specifications
Measurement / control system | |
---|---|
Flow range, based on N2 (intermediate ranges available) |
min. 0,8…40 ln/min max. 1,4…250 ln/min |
Accuracy (incl. linearity) (based on actual calibration) |
±0,5% Rd plus ±0,1% FS |
Turndown | 1:50 (in digital mode up to 1:187,5) |
Multiple fluid capability | storage of max. 8 calibration curves; optional Multi Gas / Multi Range functionality up to 10 bar abs |
Repeatability | < 0,2% Rd |
Response time | typical 0,5 sec |
Operating temperature | -10…+70°C |
Temperature sensitivity | zero: < 0,05% FS/°C; span: < 0,05% Rd/°C |
Pressure sensitivity | 0,1% Rd/bar typical N2; 0,01% Rd/bar typical H2 |
Leak integrity, outboard | tested < 2 x 10-9 mbar l/s He |
Attitude sensitivity | max. error at 90° off horizontal 0,2% at 1 bar, typical N2 |
Warm-up time | 30 min. for optimum accuracy 2 min for accuracy ± 2% FS |
Mechanical parts | |
---|---|
Material (wetted parts) | stainless steel 316L or comparable |
Pressure rating | 100 bar abs |
Process connections | compression type or face seal couplings |
Seals | standard: Viton®; options: EPDM, Kalrez® (FFKM) |
Weight | 1,3 kg |
Ingress protection (housing) | IP40 |
Electrical properties | |||
---|---|---|---|
Power supply | +15…24 Vdc | ||
Max. power consumption meter |
Supply 15 V 24 V |
at voltage I/O 95 mA 65 mA |
at current I/O 125 mA 85 mA |
Max. power consumption controller |
Supply 15 V 24 V |
at voltage I/O 290 mA 200 mA |
at current I/O 320 mA 215 mA |
PROFIBUS DP | add 53 mA (15 V supply) or 30 mA (24 V supply) | ||
PROFINET | add 77 mA (15 V supply) or 48 mA (24 V supply) | ||
EtherCAT® | add 66 mA (15 V supply) or 41 mA (24 V supply) | ||
DeviceNet™ | add 48 mA (24 V supply) | ||
Analog output/command | 0...5 (10) Vdc or 0 (4)…20 mA (sourcing output) | ||
Digital communication | standard: RS232; options: PROFIBUS DP, DeviceNet™, PROFINET, EtherCAT®, Modbus RTU or ASCII, FLOW-BUS |
Electrical connection | |
---|---|
Analog/RS232 | 9-pin D-connector (male); |
PROFIBUS DP | bus: 9-pin D-connector (female); power: 9-pin D-connector (male); |
Devicenet™ | 5-pin M12-connector (male); |
EtherCAT®/ PROFINET | 2 x RJ45 modular jack (in/out) |